These Design Standards are for information purposes only. A Service Layout Form (SLF) shall be taken out for all modifications to existing services and new services.

To request a Service Layout Form (SLF):
Call: 1-866-466-458-1236, Ext. 34820
Fax:  ​Hamilton: 905-522-8373
St.Catharines: 905-323-3461
E-mail:connections@horizonutilities.com

Everything you need to know before you start a projectEverything you need to know before you start a project

Understanding CCRACapital Cost Recovery Agreement (CCRA) brochure

Clearance Requirements from Horizon Utilities’ Live Conductors

  • 3-103 - Clearances For Conductors Over Swimming Pools
  • 3-105 - Minimum Conductor Clearances From Buildings, Permanent Structures Or Building Apparatus
  • 3-130 - Luminaire Mounting Height on Existing Hydro Distribution
  • 3U-100 - Clearances for Underground Conductors from Pools

Horizon Standard Metering Requirements

  • Metering Guide - General

  • Damaged Service Stacks & Repairs

    • For information on repair, follow this link
  • Residential metering

    • Standards
      • 25-100 – Typical connections at service mast residential only
      • 25U-202.1 – Underground secondary service residential subdivision 200A service
      • 25U-202.2 – Underground secondary service residential subdivision 400A service
      • 27-01A.1 - Residential secondary service mast detail (single story)
      • 27-01A.2 - Residential secondary service mast detail (multi story)
      • 27-01B - Residential secondary service 200A, meter base
      • 27-01C - Multiple meters installation – mounting details (residential, condominium only)
      • 27-01D - Residential secondary service installation – 200A, recessed meter base
      • 27-02 - Service entrance and meter installation 200A–120/208V or 600/347V 3-phase 4-wire (overhead supply)
      • 27-04 - Service entrance and meter installation 200A – 120/208V or 600/347V 3-phase 4-wire (underground supply)
      • 27-05 - Residential secondary service installation (400A meter base)
    • Generators
    • Microfit installations
      • 10kW or under
        • 28-25 - Micro-fit parallel connection two meter bases residential
        • 28-30 - Micro-fit parallel connection for existing 1-ph, 400A
    • Multilevel Combo (residential & commercial)
      • 27-54 – Metering installation past customer owned dry type transformer – guideline
      • 27-55 & 27-57 Switchboard - Metering installation (120/208V and 347/600V) for Customer owned primary voltage transformer – guideline
      • 27-56 & 27-58 Switchboard  - Metering installation (120/208V and 347/600V) for Horizon owned primary voltage transformer – guideline
  • Commercial metering

    (general service below 50kW, general service above 50kW and large user)
    • Secondary metering
      • 27-02 - Service entrance and meter installation 200A–120/208V or 600/347V 3-phase 4-wire (overhead supply)
      • 27-04 - Service entrance and meter installation 200A – 120/208V or 600/347V 3-phase 4-wire (underground supply)
      • 27-06 - Metering installation 400A – 120/240V 1-phase
      • 27-07 - Multiple service metering installation, commercial 400A 1-ph or 600A 3-ph
      • 27-08 - Transformer-type central metering service, 120/240V and up
      • 27-09 - Transformer-type meter installation, 3-ph (400A-600A)
      • 27-11 Switchboard - Transformer-type switchboard metering – 3 phase 800A-4000A
      • 27-13 Switchboard - Multiple service switchboard / meter-centre
      • 27-14A - Secondary service mast detail [for temporary 1-ph services – 200A or less (#2)]
    • Primary metering
    • FIT, MSP & Wholesale metering
      • 28-20 - Micro-fit parallel connection polyphase, commercial
      • 28-50 - Generator metering small or midsize capacity > 10kw 
    • Customer owned transformers
    • Multilevel Combo (commercial & residential)
      • 27-54 – Metering installation past customer owned dry type transformer – guideline
      • 27-55 & 27-57 Switchboard - Metering installation (120/208V and 347/600V) for Customer owned primary voltage transformer – guideline
      • 27-56 & 27-58 Switchboard - Metering installation (120/208V and 347/600V) for Horizon owned primary voltage transformer – guideline
    • Delta to Wye Conversion
      • 27-51 - Single meter conversion from existing delta service to solidly grounded wye service
      • 27-52 - Multi meter conversion from existing delta service to solidly grounded wye service
      • 27-53 - Metering installation 600V, 7-jaw meterbase for delta and wye services

Suite Metering Requirements